The coupling unit CU 50561-1 belongs to the equipment for measurements at powerline transmission devices. The specifications for the measurements at PLC devices are included within the standard EN-50561-1.
Combined with two line impedance stabilization networks (LISN) the coupling unit provides a coupling system which guarantees defined conditions for the measurement.
|
Frequency range: |
1.6 MHz ... 30 MHz
|
|
Symmetrical attenuation: (@ 25 Ω)
|
40 dB ± 1.5 dB
|
|
Max RF voltage: |
10 V
|
|
Dieelctric strength each wire: |
>1000 VDC
|
|
Test voltage between lines:
|
>1000 VDC
|
|
Max. power rating:
|
1000 VA
|
|
Connector Mains plug:
|
CEE 7/7
|
|
Connector Mains jack:
|
CEE 7/4
|
|
Cable length:
|
~800 mm
|
|
|
|
|
Housing dimensions:
|
|
Length:
|
68 mm
|
|
Width: |
112 mm
|
|
Hight: |
53 mm
|
|
Weight: |
310 g |