| Typ | Accessories |
| Coaxial Cables | |
| AK 9513 | 50 Ohm Coax. Cable with N plugs, individual length, usable up to 3 (5) GHz. Indiv. Cal. possible if cable longer than 3 m. Standard lengths: 3 m, 5 m, 10 m. |
| AK 9515 D | 50 Ohm Coaxial Cable with N plugs, low loss, limited flexibility, usable up to 10 (18) GHz, 10.5 mm diam. Indiv. Cal. possible if cable longer than 1 m. |
| AK 9515 E | 50 Ohm Coaxial Cable with N plugs, low loss, good flexibility, usable up to 10 (18) GHz, 10.8 mm diam. Indiv. Cal. possible if cable longer than 1 m. |
| AK 9515 G | 50 Ohm Coaxial Cable available with N- or 7/16-plugs,very low loss, high power, good flexibility, usable up to 6 GHz, 14.6 mm diam. Indiv. Cal. possible if cable longer than 1 m. |
| AK 9515 H | 50 Ohm Microwave Coaxial Cable with N- or SMA connectors, low loss, flexible, usable up to 18 GHz. Indiv. Cal. possible if cable longer than 1 m. |
| MSS 9630 | Sheath current blocking cable to avoid coupling effects caused by braid currents. Standard configuration: N-male, N-female, length ca. 0.5 m |
| Fixed Attenuators, pulse limiters | |
| DGA 9552 N | Bidirectional Attenuator N-female N-male to 18 GHz, 50 Ohm 5 Watt. Available values: 3 dB, 6 dB, 10 dB, 20, 30, 40 dB. [Case optionally available] |
| VTSD 9561 F | Diode Pulse Limiter + 10 dB Attenuation, fuse lamp, N or BNC please tell us your preference! |
| VTSD 9561 D | Diode Pulse Limiter + 20 dB Attenuation, fuse lamp, BNC |
| VTSD 9562 | Bandpass and Limiter for Partial Discharge Measurements BNC |
| Current Clamps and calibration adapters | |
| SW 9602 | Current Transformer, shielded, 0.01 - 200 MHz, Transfer Impedance: 1 Ohm for wires up to 6.5 mm. |
| SW 9603 | Current Transformer, shielded, 9 kHz - 150 MHz, Transfer Impedance: 1 Ohm for wires up to 14 mm. |
| SW 9605 | Current Transformer Clamp CISPR 22, 9 kHz - 80 MHz, Transfer Impedance: 1 Ohm for wires up to 23 mm. |
| SW 9606 | Current injection clamp for RF current injection into harnesses up to 23 mm diamter, transducer 18 dB. |
| CA 9607 | Universal calibration adapter for current clamps, test jig for ferrites, length adjustable. |
| CA 9608 | Universal calibration adapter for e.g. the following current clamps: R&S ESV-Z1, Prodyn, IT-050-1, length and height settable. |
| Baluns | |
| SY 9223-120 | Balun for transmission measurements acc. to IEC61643-21. 50 Ohm N to 120 Ohm screw terminals. |
| SY 9223-CISPR 13 | Broad band isolation transformer acc. CISPR 13 fig. A.2, 50 Ohm 75 Ohm. |
| SY 9223-PLC | 1:1 PLC balun acc. to EN 50065-2-1 2003 + A1:2005 für Immunity against small band disturbance voltage. 3 kHz - 30 MHz, BNC and banana jacks. |
| Opt. 2 µF + 50 Ohm | Opt. for SY 9223-PLC: 2 µF + 50 Ohm, in isolated housing, banana jacks. |
| SY 9501 | Balun unsymm. 50 Ohm to symm. 150 Ohm EN 55015, CISPR 15 [Picture] |
| SY 9223-17-100 | Broadband transformer 1:1,4 or 50 Ohm : 100 Ohm respectively acc. to CISPR 17 for filter measurements. 100 Ohm-side with banana jacks. 50 Ohm-side with BNC-jacks. |
| SY 9223-17-0.1 | Broadband transformer 22:1 or 50 Ohm : 0.1 Ohm respectively acc. to CISPR 17 for filter measurements. 50 Ohm-side with BNC-jacks, 0.1 Ohm-side with banana jacks. |
| Other passive devices | |
| BD 9501 | IEEE-488 Bus-Feed through for flange mounting (shielded rooms) (other feed throughs on request) |
| HPF | High Pass Filter 35 - 1000 MHz, Insertion loss at 27.12 MHz typ. 100 dB |
| TF 130-150 | Test Fixture for Ford RI 130/ 150 Per EMC-CS-2009 |
| VDHH 9502 | Van der Hoofden test head with protection network acc. IEC62493 or VDE 0848-493. Program for the calculation of F-factor |
| CISPR 17 Equipment | Transformers, fixtures and adapters to measure filters, ferrites and other passive components. Detailed product list and data sheets on request. |
| CCC 9224 | Capacitive coupling clamp for transients acc. to ISO 7637-3 or DC-10614 B.5. |
| Preamplifiers | |
| BBV 9743 | Broadband Coaxial Preamplifier gain max. 30 dB, 10 MHz ? 6 GHz, low noise floor, N-jack N-plug, including power supply. |
| BBV 9744 | Broadband Coaxial Preamplifier gain max. 30 dB, 9 kHz 6 GHz, low noise floor, N-jack N-plug, including power supply. |
| BBV 9745 | Broadband Coaxial Preamplifier gain max. 30 dB, 9 kHz 2 GHz, low noise floor, N-jack N-plug, improved ESD protection, including power supply. |
| BBV 9718 | Broadband Coaxial Preamplifier typ. 33 dB, 1 - 18 GHz with fixture for 22 mm |
| BBV 9718 Opt Akku | Option: Rechargeable battery pack for BBV 9718 or 9719. [Picture] |
| BBV 9718 Opt. ALCS 2-24A | Battery charger ALCS 2-24A for rechargeable battery pack |
| BBV 9718 Opt. PS | Option: Power supply for BBV 9718 or 9719. |
| BBV 9719 | Broadband Coaxial Preamplifier typ. 33 dB, 18-26.5 GHz, power supply 12 V 300 mA necessary. Including short cable with SMA plugs to connect the BBV 9719 with the antenna (for example BBHA 9170). |
| BBV 9719 Opt. PS | Option Power supply for BBV 9718 or 9719. |
| BBV 9719 Opt. Battery | Option Rechargeable battery pack for BBV 9718 or 9719 [Picture] |
| BBV 9719 Opt. ALCS 2-24A | Battery charger ALCS 2-24A for rechargeable battery pack. |
| BBV 9721 | Broadband Coaxial Preamplifier typ. 30 dB, 18-40 GHz. Including short cable with 2.92 plugs to connect the BBV 9721 with the antenna (for example BBHA 9170). Noise figure 5.5 dB, P1dBmin=15 dBm, VSWR max in/out = 2,6. |
| PS 9721 | Power supply unit for BBV 9721 including cables with secuity plugs, can be used for 110 and 230 V. |
| Reference radiators, comb generators | |
| SG 9301 | Spectrum Generator 30-1000 MHz, spectrum lines switchable 100 Hz - 1 MHz, N-female connector, charger ACS 110 required, main application: reference radiator (antenna required e.g. UBAA 9114 with BBVU 9135) |
| SG 9302 | Comb generator 0.1 18 GHz, spectrum lines every 100 MHz, battery driven, including charger for 230 V. |
| Field probes | |
| VUFM 1670 | E-Field Meter 70 kHz-2.5 GHz, 1V/m-300V/m, linear polarized, charger ACS 110 required. |
| VUFM 1671 | LCD-Display Unit for VUFM 1670 with 5 m fibre optical link, charger ACS 110 required. |
| VUFM 1672 | LCD-Display Unit VUFM 1672 for E - Field-Meter VUFM 1670
with optical link and IEEE 488 / GPIB - Interface.
|
| Other active devices | |
| VHIC 9260 | Antenna Impedance converter acc. CISPR 25 9 kHz - 30 (120) MHz. |
| VHIC 9260 Opt. ACS 110 | Option: Charger ACS 110 for VHIC 9260. |
| CVP 9222 | High Impedance Capacitive Voltage Probe acc. to CISPR 22, EN 55022 C 1.3. Frequency range: 9 kHz ? 100 MHz.
|
| CVP 9222 Opt. ACS 110 | Option: Charger ACS 110 for CVP 9222. |
| Opt. CAL 9222 | Option: Calibration Adapter for CVP 9222. |