| Typ | CDN 0.15 - 230 MHz, IEC 1000-4-6, EN 61000-4-6 |
| M-Type CDN for mains lines | |
| CDN M1 | CDN for Earth conductor 250V AC / 1,000V DC, 16A, 150kHz - 230MHz [Picture1] [Picture2] |
| CDN M1-32A | CDN for Earth conductor 250V AC / 1,000V DC, 32A, 150kHz - 230MHz |
| CDN M1-32A/1000V | CDN for Earth conductor 1,000V AC / 1,000V DC, 32A, 150kHz - 80MHz |
| CDN M1-50A | CDN for Earth conductor 250V AC / 750V DC, 50A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M1-75A | CDN for Earth conductor 250V AC / 750V DC, 75A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M1-100A | CDN for Earth conductor 250V AC / 750V DC, 100A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M2 | CDN for two mains supply lines 250V AC / 250V DC, 16A, 150kHz - 300MHz, AE port with IEC 320 connector [Picture1] [Picture2] |
| CDN M2 Banana | CDN for two mains supply lines 250V AC / 1,000V DC, 16A, 150kHz - 230MHz, AE port with banana connectors |
| CDN M2-500V | CDN for two mains supply lines 500V AC / 1,000V DC, 16A, 150kHz - 80MHz |
| CDN M2-750V | CDN for two mains supply lines 750V AC / 1,000V DC, 16A, 150kHz - 80MHz |
| CDN M2-1000V | CDN for two mains supply lines 1,000V AC / 1,000V DC, 16A, 150kHz - 80MHz |
| CDN M2-32A | CDN for two mains supply lines 250V AC / 1,000V DC, 32A, 150kHz - 230MHz |
| CDN M2-32A/750V | CDN for two mains supply lines 750V AC / 1,000V DC, 32A, 150kHz - 80MHz |
| CDN M2-32A/1000V | CDN for two mains supply lines 1,000V AC / 1,000V DC, 32A, 150kHz - 80MHz |
| CDN M2-50A | CDN for two mains supply lines 250V AC / 750V DC, 50A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M2-50A/750V | CDN for two mains supply lines 750V AC / 750V DC, 50A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M2-75A | CDN for two mains supply lines 250V AC / 750V DC, 75A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M2-100A | CDN for two mains supply lines 250V AC / 750V DC, 100A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M2/M3 | CDN for two or three supply lines, switchable, 250V AC / 250V DC, 16A, 150kHz - 300MHz, AE port with IEC 320 connector, CDNE M2 or CDNE M3 for CISPR 15 also available! |
| CDN M3 | CDN for three mains supply lines 250V AC / 250V DC, 16A, 150kHz - 300MHz, AE port with IEC 320 connector [Picture1] [Picture2] |
| CDN M3 Banana | CDN for three mains supply lines 250V AC / 1,000V DC, 16A, 150kHz - 230MHz, AE port with banana connectors |
| CDN M3-500V | CDN for three mains supply lines 500V AC (L+N+PE) / 1,000V DC, 16A, 150kHz - 80MHz |
| CDN M3-400V Delta | CDN for three mains supply lines 3x400V AC (L1+L2+L3) / 1,000V DC, 16A, 150kHz - 230MHz |
| CDN M3-32A | CDN for three mains supply lines 250V AC / 1,000V DC, 32A, 150kHz - 230MHz |
| CDN M3-32A/400V Delta | CDN for three mains supply lines 3x400V AC (L1+L2+L3), 32A, 150kHz - 230MHz |
| CDN M3-32A/750V | CDN for three mains supply lines 750V AC (L+N+PE) / 1,000V DC, 32A, 150kHz - 80MHz |
| CDN M3-32A/750V Delta | CDN for three mains supply lines 3x750V AC (L1+L2+L3) / 1,000V DC, 32A, 150kHz - 80MHz |
| CDN M3-50A | CDN for three mains supply lines 250V AC / 750V DC, 50A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M3-75A | CDN for three mains supply lines 250V AC / 750V DC, 75A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M3-100A | CDN for three mains supply lines 250V AC / 750V DC, 100A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M4 PE | CDN for four mains supply lines (L1+L2+L3+PE) 3x400V AC, 16A, 150kHz - 230MHz |
| CDN M4 N | CDN for four mains supply lines (L1+L2+L3+N) 3x400V AC, 16A, 150kHz - 230MHz |
| CDN M4 PE-32A | CDN for four mains supply lines (L1+L2+L3+PE) 3x400V AC, 32A, 150kHz - 230MHz |
| CDN M4 N-32A | CDN for four mains supply lines (L1+L2+L3+N) 3x400V AC, 32A, 150kHz - 230MHz |
| CDN M4 PE-32A/750V | CDN for four mains supply lines (L1+L2+L3+PE) 3x750V AC, 32A, 150kHz - 80MHz |
| CDN M4 N-32A/750V | CDN for four mains supply lines (L1+L2+L3+N) 3x750V AC, 32A, 150kHz - 80MHz |
| CDN M4 PE-75A | CDN for four mains supply lines (L1+L2+L3+PE) 3x400V AC, 75A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M4 N-75A | CDN for four mains supply lines (L1+L2+L3+N) 3x400V AC, 75A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M4 PE-100A | CDN for four mains supply lines (L1+L2+L3+PE) 3x400V AC, 100A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M4 N-100A | CDN for four mains supply lines (L1+L2+L3+N) 3x400V AC, 100A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M4 N-100A/750V | CDN for four mains supply lines (L1+L2+L3+N) 3x750V AC, 100A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M5 | CDN for five mains supply lines (L1+L2+L3+N+PE) 3x400V AC, 16A, 150kHz - 230MHz |
| CDN M5-32A | CDN for five mains supply lines (L1+L2+L3+N+PE) 3x400V AC, 32A, 150kHz - 230MHz |
| CDN M5-32A/750V | CDN for five mains supply lines (L1+L2+L3+N+PE), 3x750V AC, 32A, 150kHz - 80MHz |
| CDN M5-75A | CDN for five mains supply lines (L1+L2+L3+N+PE) 3x400V AC, 75A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M5-75A/750V | CDN for five mains supply lines (L1+L2+L3+N+PE) 3x750V AC, 75A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| CDN M5-100A | CDN for five mains supply lines (L1+L2+L3+N+PE) 3x400V AC, 100A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port |
| S-Type CDN for shielded lines and coaxial cables | |
| CDN S1-50 BNC | CDN for screened coaxial cable, single line, 50ohm BNC, 100V AC / 100V DC, 0.25A, 150kHz - 230MHz |
| CDN S1-50 N | CDN for screened coaxial cable, single line, 50ohm N, 100V AC / 100V DC, 0.25A, 150kHz - 230MHz |
| CDN S1-50 SMA | CDN for screened coaxial cable, single line, 50ohm SMA, 100V AC / 100V DC, 0.25A, 150kHz - 230MHz |
| L-801 S1-75 BNC | CDN for screened coaxial cable, single line, 75ohm BNC, 100V AC / 100V DC, 0.25A, 150kHz - 230MHz |
| CDN S1-75 N | CDN for screened coaxial cable, single line, 75ohm N, 100V AC / 100V DC, 0.25A, 150kHz - 230MHz |
| CDN S2 BNC | CDN for two screened cables, BNC conn., 100V AC / 100V DC, 1.5A, 150kHz - 80MHz |
| CDN S4 BNC | CDN for four screened cables, BNC conn., 100V AC / 100V DC, 1.5A, 150kHz - 80MHz |
| CDN S4 USB | CDN for screened cable, four lines, USB A conn., 100V AC / 100V DC, 1A, 150kHz - 230MHz |
| CDN S4-3A BNC | CDN for screened cable, four lines, BNC conn., 100V AC / 100V DC, 3A, 150kHz - 80MHz |
| CDN S8 RJ45 | CDN for screened cable, eight lines, RJ45 conn., 100V AC / 100V DC, 1.5A, 150kHz - 230MHz |
| CDN S9 | CDN for screened cable, nine lines, Sub-D9, 125V AC / 125V DC, 1.5A, 150kHz - 230MHz |
| CDN S15 | CDN for screened cable, 15 lines, Sub-D15, 125V AC / 125V DC, 1.5A, 150kHz - 230MHz |
| CDN S15 VGA | CDN for screened cable, 15 lines, VGA conn., 125V AC / 125V DC, 1.5A, 150kHz - 230MHz |
| CDN S25 | CDN for screened cable, 25 lines, Sub-D25, 125V AC / 125V DC, 1.5A, 150kHz - 230MHz |
| CDN S37 | CDN for screened cable, 37 lines, Sub-D37, 125V AC / 125V DC, 0.25A, 150kHz - 80MHz |
| CDN S50 | CDN for screened cable, 50 lines, Sub-D50, 125V AC / 125V DC, 0.25A, 150kHz - 80MHz |
| T-Type CDN for balanced unscreened communication lines | |
| CDN T2 | CDN for unscreened balanced pair, RJ11/banana conn, 63V AC / 100V DC, 1.5A, 150kHz - 230MHz |
| CDN T2-3A | CDN for unscreened balanced pair, banana conn, 63V AC / 100V DC, 3A, 150kHz - 80MHz |
| CDN T2-5A | CDN for unscreened balanced pair, banana conn, 63V AC / 100V DC, 5A, 150kHz - 80MHz |
| L-801 T4 Banana | CDN for two unscreened balanced pairs, banana conn, 63V AC / 100V DC, 1.5A, 150kHz - 230MHz |
| CDN T4 XLR | CDN for two unscreened balanced pairs, XLR conn, 50V AC / 50V DC, 1.5A, 150kHz - 230MHz |
| CDN T4 RJ45 | CDN for two unscreened balanced pairs, RJ45 conn, 63V AC / 100V DC,1.5A, 150kHz - 230MHz |
| CDN T4-3A | CDN for two unscreened balanced pairs, banana conn, 63V AC / 100V DC, 3A, 150kHz - 80MHz |
| CDN T8 RJ45 | CDN for 4 unscreened balanced pairs, RJ45 conn, 63V AC / 100V DC, 1.5A, 150kHz - 230MHz |
| CDN T8-3A | CDN for 4 unscreened balanced pairs, banana conn, 63V AC / 100V DC, 3A, 150kHz - 80MHz |
| AF-Type CDN for non balanced data lines | |
| CDN AF2 | CDN for 2 unscreened unbalanced lines, banana conn, 63V AC /100V DC, 1.5A, 150kHz - 300MHz, incl. VDF data for CISPR 15 |
| CDN AF2-250V | CDN for 2 unscreened unbalanced lines, banana conn, 250V AC / 250V DC, 1.5A, 150kHz - 80MHz |
| CDN AF3 | CDN for 3 unscreened unbalanced lines, banana conn, 63V AC / 100V DC, 1.5A, 150kHz - 300MHz, incl. VDF data for CISPR 15 |
| CDN AF3-3A | CDN for 3 unscreened unbalanced lines, banana conn, 63V AC / 100V DC, 3A, 150kHz - 80MHz |
| CDN AF3-250V | CDN for 3 unscreened unbalanced lines, banana conn, 250V AC / 250V DC, 1.5A, 150kHz - 80MHz |
| CDN AF4 | CDN for 4 unscreened unbalanced lines, banana conn, 63VAC / 100V DC, 1.5A, 150kHz - 230MHz |
| CDN AF5 | CDN for 5 unscreened unbalanced lines, banana conn, 63V AC / 100V DC, 1.5A, 150kHz - 80MHz |
| CDN AF6 | CDN for 6 unscreened unbalanced lines, banana conn, 63V AC / 100V DC, 1.5A, 150kHz - 80MHz |
| CDN AF6-250V | CDN for 6 unscreened unbalanced lines, banana conn, 250V AC / 250V DC, 1.5A, 150kHz - 80MHz |
| CDN AF8 | CDN for 8 unscreened unbalanced lines, banana conn, 63V AC / 100V DC, 1.5A, 150kHz - 80MHz |
| CDN AF10 | CDN for 10 unscreened unbalanced lines, D-Sub15 conn, 63V AC / 100V DC, 1.5A, 150kHz - 80MHz |
| CDN AF15 | CDN for 15 unscreened unbalanced lines, D-Sub15 conn, 63V AC / 100V DC, 1.5A, 150kHz - 80MHz |
| CDN AF25 | CDN for 25 unscreened unbalanced lines, D-Sub25 conn, 63V AC / 100V DC, 1.5A, 150kHz - 80MHz |
| Special CDN | |
| CDN CAN-4 | CDN 4 CAN-Bus, 4-wire, unscreened, 48V, 2A (supply lines, pins 3 (GND) and 9 (V+)) and 48V, 2A (CAN-BUS lines, pins 2 CAN-L and 7 CAN-H), 150kHz - 230MHz, Sub-D9 connector |
| CDNE for emission measurement on luminaries acc. EN 55015 | |
| CDNE M2 | CDNE with tight tolerances for CISPR 15 emission measurements with 2 mains conductors can also be used as CDNE AF2. |
| CA CDNE M2 Part A | Part A of the calibration or short adapter for CDNE M2 |
| CA CDNE Part B | Part B of the calibration or short adapter for CDNE M2 or M3 |
| SR100-6W | Adapter 150 to 50 Ohm for CDNE or ISN e.g. ISN S8 or CDNE M2, 0-500 MHz, 6 W, connectors: BNC female, 4 mm security banana jack. |
| CDNE M3 | CDNE with tight tolerances for CISPR 15 emission measurements with 3 mains conductors. |
| CA CDNE M3 Part A | Calibration or short adapter for CDNE M3 part A. |
| CDN for IEC 60945 or EN 61326-3-2 10kHz - 80MHz | |
| CDN M1-10kHz | CDN for Earth conductor 250V AC / 1,000V DC, 16A, 10kHz - 80MHz |
| CDN M2-10kHz | CDN for two mains supply lines 250V AC / 1,000V DC, 16A, 10kHz - 80MHz |
| CDN M2-10kHz/500V | CDN for two mains supply lines 500V AC / 1,000V DC, 16A, 10kHz - 80MHz |
| CDN M3-10kHz | CDN for three mains supply lines 250V AC / 1,000V DC, 16A, 10kHz - 80MHz |
| CDN T2-10kHz | CDN for unscreened balanced pair, RJ11/banana conn, 63V AC / 100V DC, 1.5A, 10kHz - 80MHz |
| CDN T8-10kHz | CDN for 4 unscreened balanced pairs, RJ45 conn, 63V AC / 100V DC, 1.5A, 10kHz - 80MHz |
| CDN AF2-10kHz | CDN for 2 unscreened unbalanced lines, banana conn, 63V AC / 100V DC, 1.5A, 10kHz - 80MHz |
| CDN AF3-10kHz | CDN for 3 unscreened unbalanced lines, banana conn, 63V AC / 100V DC, 1.5A, 10kHz - 80MHz |
| L-801 AF4/10kHz | CDN for 4 unscreened unbalanced lines, banana conn, 63V AC / 100V DC, 1.5A, 10kHz - 80MHz |
| CDN AF6-10kHz | CDN for 6 unscreened unbalanced lines, banana conn, 63V AC / 100V DC, 1.5A, 10kHz - 80MHz |
| CDN AF8-10kHz | CDN for 8 unscreened unbalanced lines, banana conn, 63V AC / 100V DC, 1.5A, 10kHz - 80MHz |
| Calibration or short adapters for CDN | |
| CWS-CAL | Basic calibration kit including 1ea R-100N, 1ea 50cm BNC cable, plastic case |
| R-100N | Adapter 150-to-50 Ohm for CDN |
| CA M1 | Calibration adapter for all CDN M1 models, EUT port and AE port |
| CA M2/M3/AF3(N) | Calibration adapter for CDN M2-32A (AE port only), M3, M3-32A (EUT port and AE port), CDN M2/M3 (EUT port only) and CDN AF3 (EUT port and AE port) |
| CAA M2/M3N | Cal kit for CDN M2/M3, CDN M2 and CDN M3 (AE-port only) incl. 1ea Adapter IEC 60320, 1ea R-100N, 1ea T-50 |
| CA T2/AF2/M2N | Calibration adapter for CDN T2, AF2 (EUT port and AE port) and M2 and M2-32A (EUT port only) |
| CA M2/50-100 | Calibration adapter for CDN M2-50A, M2-75A and M2-100A (EUT port and AE port) |
| CA M3/50-100 | Calibration adapter for CDN M3-50A, M3-75A and M3-100A (EUT port and AE port) |
| CA T4/AF4/M4 | Calibration adapter for CDN T4 and CDN AF4 (EUT port and AE port), CDN M4 and CDN M4-32A (AE port) |
| CA M4N | Calibration adapter for CDN M4 N and CDN M4 PE (EUT port) |
| CA M4/50-100 | Calibration adapter for CDN M4-50A, M4-75A and M4-100A (EUT port and AE port) |
| CA AF5/M5 | Calibration adapter for CDN AF5 (EUT port and AE port) and CDN M5 (AE port), M5-32A (AE port) and former CDN M5(16A) (EUT port and AE port) |
| CA M5N | Calibration adapter for CDN M5 and M5-32A (EUT port) |
| CA M5/50-100 | Calibration adapter for CDN M5-50A, M5-75A and M5-100A (EUT port and AE port) |
| CA T8RJ45 | Calibration adapter for CDN T8RJ45 (EUT port and AE port) |
| CA AF8 | Calibration adapter for CDN AF8 and T8-3A (EUT port and AE port) |
| CA AF10 | Calibration adapter for CDN AF10 (EUT port and AE port) |
| CA S1 | Calibration adapter for CDN S1 |
| CA S2/S4 | Calibration adapter for CDN S2 BNC and CDN S4 BNC |
| CA S4-USB | Calibration adapter for CDN S4-USB |
| CA S8-RJ45 | Calibration adapter for CDN S8RJ45 |
| CA S9/S15/S25 | Calibration adapter for CDN S9, CDN S15 and CDN S25 |
| CA S37 | Calibration adapter for CDN S37 |
| ! ! ! | For CDN S-Type only one calibration adapter is required, for all other types the standard recommends to also terminate the AE port. One piece of calibration adapter is automatically included in the delivery of every Luethi CDN |
| CA EM | Cal kit. for EM 101 incl. 1ea R-100N, 1ea T-50, 1ea connection cable (requires CWS CAL or additional R-100N)
See also "Cable EM/FTC 101" as additional option.
|
| Cable EM/FTC 101 | Cable with a length of 1750mm to calibrate an EM 101 together with a FTC 101 (Additional option for item CA EM) |